Commercial Air Pressure Test with Smoke Test- Sutterton, Lincolnshire. Client Lagan Construction Group Ltd

Posted on

Commercial Air Pressure Test, Sutterton, Lincolnshire, Mercedes

EPS Group were contacted late in the project to complete a Commercial Air Pressure Test (Air Tightness Test) for a large truck repair center in Sutterton, Lincolnshire.  Unfortunately, the building failed to achieve the required Air Permeability of 5 m3/h/m2 during the first test. A result of approx. 27 m3/h/m2 was recorded.

EPS Group worked with the client to complete Thermal Image Diagnosis along with Full Building Smoke Testing to determine the areas of Air Leakage.

Several tests were required with a final air permeability of 3.6 m3/h/m2 was achieved.

Commercial Air Pressure Test with Smoke Test, Sutterton, Lincolnshire. Internal view of smoke test
Commercial Air Pressure Test with Smoke Test, Sutterton, Lincolnshire, undertaken by EPS Group
Commercial Air Pressure Test with Thermal Image Diagnosis, Sutterton, Lincolnshire. Leakage around the roller doors
Commercial Air Pressure Test with Thermal Image Diagnosis, Sutterton, Lincolnshire by EPS Group

Call us today to discuss your specific requirements on
0115 7270549